Multimeters
Application field:
- This instrument has been designed for use in environments of pollution degree 2.
- It can be used for VOLTAGE measurements on installations of CAT III 1000V or CAT IV 600V.
- Only the original test leads supplied along with the instrument guarantee compliance with the safety standards in force. They must be in a good condition and, if necessary, replaced with identical ones.
- Do not test nor connect to any circuit exceeding the specified overload protection.
- Before connecting the test probes to the installation make sure that the rotary selector is positioned on the right function.
- Make sure that LCD and rotary selector indicate the same function.
Features
MODEL | TM-81 | TM-82 | TM-86 | TM-87 | TM-88 |
Backlit | • | • | • | • | |
Bargraph | • | • | |||
DC Voltage | • | • | • | ||
AC sine voltage | • | • | |||
DC Current | • | ||||
AC sine wave Voltage | • | ||||
AC sine wave Current | • | ||||
DC and AC TRMS Voltage |
• | • | |||
DC and AC TRMS Current |
• | • | |||
Resistance | • | • | • | • | • |
Continuity test | • | • | • | • | • |
Diode test | • | • | • | • | • |
Temperature with type K probe |
• | ||||
Duty cycle | • | ||||
Frequency | • | • | • | ||
Capacitance | • | • | • | ||
Auto power off | • | • | • | • | • |
Range hold | • | • | • | • | • |
Data hold | • | • | • | • | • |
MAX | • | • | Max/Min | Max/Min | |
Peak hold | • | • | |||
REL | • | • | • |
Technical Specifications
TECHNICAL FEATURES |
TM-81 | TM-82 | TM-86 | TM-87 | TM-88 | ||
Display | 3½ LCD with max. reading 1999 counts +symbol and decimal point |
3¾ LCD with max. Reading 3999 counts +symbol and decimal point |
4 LCD with max. reading 3999 counts +symbol decimal point sign and barograph |
||||
Sampling rate | 2.5/s | ||||||
DC Voltage | 0.1mV~600V (0.8%+1) |
0.1mV~600V (0.8%+2) |
0.1mV~1000V (0.5%+2) |
||||
AC Voltage | 0.001V~600V (1.5%+3) |
0.001V~600V (0.8%+3) |
|||||
AC TRMS Voltage | 0.1mV~750V (1.3%+5) |
||||||
DC Current | 0.01A~10A (1.2%+3) |
0.1µA~10A (1.0%+3) |
|||||
AC Current | 0.01A~10A (2.0%+5) |
||||||
AC TRMS Current | 0.1µA~10A (1.5%+5) |
||||||
Resistance | 200Ω,2kΩ,20kΩ, 200kΩ,2MΩ,20MΩ |
400Ω,4kΩ,40kΩ,400kΩ,4MΩ,40MΩ | |||||
Accuracy | ±(1.0%+3) | ±(1.0%+2) | ±(1.0%+2) | ||||
Overload protection |
600V rms | 1000V rms | |||||
Diode Test | √(1.5V) | Continuity Test | √ | √ | √ | ||
Continuity Test | √ | √ | √ | √ | √ | ||
Temperature with K probe |
-40°C~800°C -40°F~1382°F |
||||||
Accuracy | °C | (2.0%rdg + 3dgt) | |||||
°F | (2.0%rdg + 5dgt) | ||||||
Temperature Use T10 adapter and K-type probe |
-40°C~80°C -40°F~1382°F |
||||||
Accuracy | °C | (2.0%rdg +3dgt) | |||||
°F | (2.0%rdg +5dgt) | ||||||
Frequency (Autorange) |
0.01Hz~99.99KHz | 1Hz~100KHz | |||||
Duty cycle (Autorange) |
20~80% | ||||||
Capacitance (Autorange) |
5nF,50nF,500nF, 5µF,50µF,100µF |
4nF,40nF,400nF, 4µF,40µF,400µF,4mF,40mF |
|||||
Accuracy | ±(3%+5) | ±(1%+5) | |||||
ACCESSORIES | Adapter for connection type K probe -T10 | Adapter for connection type K probe -T10 |