whatsapp

HIGH VOLTAGE CLAMP TESTER

HCL-3000D

FEATURES

  • Low Range Measurement of 1mA~20A in Hi-Voltage Circuit up to 7KV
  • Easy Operation – Push & Pull Auto Opening/ closing CT
  • Safety Design & Function
  • Auto Power off Function & Waterdrop Proof Structure

HCL-5000D

FEATURES

  • Wide Range Measurement of 0.1A〜600A.
  • Easy Operation – Push & Pull Auto Opening/ closing CT
  • Safety Design & Function
  • Auto Power off Function & Waterdrop Proof Structure

HCL-1000DM

FEATURES

  • Safe AC current measurement by hot stick on circuit having internal voltage from AC 80V to AC 46KV.
  • Provides wide range of current measurement from AC 0.01A to 600A.
  • Peak Hold Function and with UNIVERSAL adapter for attachment of hot stick.

HCL-9000S

FEATURES

  • Safe AC current measurement by optical isolated transmission method on circuit having internal voltage from AC 80V to AC 23kV.
  • Useful analog signal data output for the recorder.
  • Sealed to withstand water and contaminants.
  • Provides the smooth and easy clamping for the cable with special made “PUSH TO OPEN” mechanism

HCL-36UX

FEATURES

  • No need to clamp on the overhead distribution line up to 36kV for load current measurement.
  • Display measurement value on your smartphone through blue-tooth connecting.
  • Measurement value can be kept in the our cloud server.
  • In addition to measured values, location registration by GPS, temperature and humidity, date and time can also be saved.
  • Low Pass Filter
  • Holds up to four readings
  • Separate display connection by Blue-tooth
Highlights HCL-3000D HCL-5000D HCL-1000DM HCL-9000S HCL-36UX
Limtation of Circuit Volatge 80 ~ 7KV 80 ~ 46KV 80 ~ 23KV AC 36kV
Range 0~2000mA/20A (50/60 Hz) 0 ~ 20/600 A(50/60 Hz) AC 300A/3000A (Auto) (50/60 Hz)
Resolution 1 mA / 0.01 A 0.01 A / 1 A 0.1 A
Accuracy ±2%rdg±8dgt 0〜400A〜±2%rdg±8dgt
400A〜600A〜±3%rdg±8dgt
±1%rdg±2dgt
Specifications HCL-3000D HCL-5000D HCL-1000DM HCL-9000S HCL-36UX
Measuring Function : AC leakage/line current AC line current
Measuring Method : Dual integration mode Integral
Display : 3.5 digit LCD max. reading of 1999 with annunciators Optional: MDU-100X (display unit)
Jaw opening Capability : φ35mm 55.4mm "Type U"
Data hold Function : “DH” mark on LCD - “DH” mark on LCD -
Peak Hold Function - - LED lamp is lightning when push the peak hold switch. - Temperature/ Humidity display : Approximate value by our APP ”M-tracer”
Auto Power off : Automatically power off mode, approx. 5minutes after the power switch on. - - Power On/Off Other operations: On the APP or Display unit
Overload Indication: Blanking of all digits except MSD 1 Blanking of all digits except MSD1 (Except 600A range) -
Sampling time : 2 times/sec
Low Battery Indication : [B]mark on LCD. ”B” mark on LCD readout CT part;Red LED lamp Display/grip part;”B” mark on LCD readout By LED flashing
Insulation resistance (Between operation handle and core of CT) 100MΩ or more by DC 1000V insulation tester
Withstanding voltage AC 15kV, 1 minute (Between operation handle and core of CT) AC 100kV, 5 minute (Between operation handle and core of CT) AC 46kV, 5 minute (Between operation handle and core of CT) AC 70kV/5min (Between hot stick connector and core of CT)
Operating Temperature : 0~40℃, less than 80%RH without condensing -20~60℃ 20~96% Lithium battery
5~45℃ 20~96% Alkaline battery
Power supply : 1.5V (“AAA” size)×2 CT part;1.5V (“AAA” size)×3 Display/grip part; 1.5V (“AAA” size)×2 AAA size battery×4
Size 70(W)×356(H)×68(D)mm,approx. . 70(W)×290(H)×32(D)㎜ (When retracted) 70(W)×550(H)×48(D)㎜ (When retracted)
70(W)×1110(H)×48(D)㎜ (When steretched)
W179.6×H400×D90.4mm
Weight 370gs 400gs Approx. 350gs including batteries Approx. 800g Approx 1550g (including battery weight)
Accessories : Batteries, UM-4..................2pcs.
Carrying Case....................1pce.
Instruction manual..............1pce.
-