HCL-3000D
FEATURES
- Low Range Measurement of 1mA~20A in Hi-Voltage Circuit upto 7 kV
- Easy Operation – Auto Opening/Closing CT
- Safety Design & Function
- Auto Power off Function & Waterdrop Proof Structure
HCL-3000D
1 file(s) 4 MB
HCL-5000D
FEATURES
- Wide Range Measurement of 0.1A〜600A.
- Easy Operation – Auto Opening/Closing CT
- Safety Design & Function
- Auto Power off Function & Waterdrop Proof Structure
HCL-5000D
1 file(s) 4 MB
HCL-1000DM
FEATURES
- Safe AC current measurement by hot stick on circuit having internal voltage from 80 V AC to 46 kV AC.
- Provides wide range of current measurement from AC 0.01A to 600A.
- Peak Hold Function and with universal adapter for attachment of hot stick.
HCL-1000DM
1 file(s) 4 MB
HCL-9000S
FEATURES
- Safe AC current measurement by optical isolated transmission method on circuit having internal voltage from 80 V AC to 23 kV AC.
- Useful analog signal data output for the recorder.
- Sealed to withstand water and contaminants.
- Provides the smooth and easy clamping for the cable with special made “PUSH TO OPEN” mechanism
HCL-9000S
1 file(s) 4 MB
HCL-36UX
FEATURES
- No need to clamp on the overhead distribution line up to 36kV for load current measurement.
- Display measurement value on your smartphone through Bluetooth connecting.
- Measurement value can be kept in the our cloud server.
- In addition to measured values, location registration by GPS, temperature and humidity, date and time can also be saved.
- Low Pass Filter
- Holds up to four readings
- Separate display connection by Bluetooth
HCL-36UX
1 file(s) 4 MB
Highlights | HCL-3000D | HCL-5000D | HCL-1000DM | HCL-9000S | HCL-36UX |
---|---|---|---|---|---|
Limtation of Circuit Volatge | 80 ~ 7KV | 80 ~ 46KV | 80 ~ 23KV | AC 36kV | |
Range | 0~2000mA/20A (50/60 Hz) | 0 ~ 20/600 A(50/60 Hz) | AC 300A/3000A (Auto) (50/60 Hz) | ||
Resolution | 1 mA / 0.01 A | 0.01 A / 1 A | 0.1 A | ||
Accuracy | ±2%rdg±8dgt | 0〜400A〜±2%rdg±8dgt 400A〜600A〜±3%rdg±8dgt | ±1%rdg±2dgt | ||
Specifications | HCL-3000D | HCL-5000D | HCL-1000DM | HCL-9000S | HCL-36UX |
Measuring Function : | AC leakage/line current | AC line current | |||
Measuring Method : | Dual integration mode | Integral | |||
Display : | 3.5 digit LCD max. reading of 1999 with annunciators | Optional: MDU-100X (display unit) | |||
Jaw opening Capability : | φ35mm | 55.4mm “Type U” | |||
Data hold Function : | “DH” mark on LCD | – | “DH” mark on LCD | – | |
Peak Hold Function | – | – | LED lamp is lightning when push the peak hold switch. | – | Temperature/ Humidity display : Approximate value by our APP ”M-tracer” |
Auto Power off : | Automatically power off mode, approx. 5minutes after the power switch on. | – | – | Power On/Off Other operations: On the APP or Display unit | |
Overload Indication: | Blanking of all digits except MSD 1 | Blanking of all digits except MSD1 (Except 600A range) | – | ||
Sampling time : | 2 times/sec | ||||
Low Battery Indication : | [B]mark on LCD. | ”B” mark on LCD readout | CT part;Red LED lamp Display/grip part;”B” mark on LCD readout | By LED flashing | |
Insulation resistance (Between operation handle and core of CT) | 100MΩ or more by DC 1000V insulation tester (Between hot stick connector and core of CT) | ||||
Withstanding voltage | AC 15kV, 1 minute (Between operation handle and core of CT) | AC 100kV, 5 minute (Between operation handle and core of CT) | AC 46kV, 5 minute (Between operation handle and core of CT) | AC 70kV/5min (Between hot stick connector and core of CT) | |
Operating Temperature : | 0~40℃, less than 80%RH without condensing | -20~60℃ 20~96% Lithium battery 5~45℃ 20~96% Alkaline battery | |||
Power supply : | 1.5V (“AAA” size)×2 | CT part;1.5V (“AAA” size)×3 Display/grip part; 1.5V (“AAA” size)×2 | AAA size battery×4 | ||
Size | 70(W)×356(H)×68(D)mm,approx. . | 70(W)×290(H)×32(D)㎜ (When retracted) | 70(W)×550(H)×48(D)㎜ (When retracted) 70(W)×1110(H)×48(D)㎜ (When steretched) | W179.6×H400×D90.4mm | |
Weight | 370g | 400g | Approx. 350g including batteries | Approx. 800g | Approx 1550g (including battery weight) |
Accessories : | Batteries, UM-4………………2piece. Carrying Case………………..1piece. Instruction manual…………..1piece. | – |