DGA Series

Transfix DGA 500

The Transfix™ DGA 500 is an on-line monitoring unit that measures five individual dissolved gases and moisture, and provides both on-line monitoring and key exploratory diagnostics. It uses GE’s advanced Photo-acoustic spectroscopy (PAS) technology, made popular due to its accuracy, repeatability and lack of consumable through its bigger brother the Kelman™ Transfix.

Get a quote
Get Demo

Features

  • Automated, on-line multi-gas and moisture monitoring
  • Provides early identification of arcing issues before they become critical failures
  • Ability to perform Duval’s triangle DGA diagnostic
  • Easily replaceable with a full nine gas unit

Applications

Power Utilities:

  • Middle of the road solution for medium-criticality transformers
  • Monitoring together with remote exploratory diagnostic

Industrial Plants:

  • Reduces the risk of process interruption due to power failure
  • Minimizes costly production downtime

Technical Specifications

Sensor

  • Automated head space gas extraction
  • Photo-acoustic spectroscopy(PAS)gas measurement
  • Thin film capacitive moisture sensor

Measurements

  • Hydrogen(H2):5-5,000ppm
  • Carbon Monoxide(CO):2-50,000ppm
  • Acetylene(C2H2):0.5-50,000ppm
  • Ethylene(C2H4):2-50,000ppm
  • Methane(CH4):2-50,000ppm
  • Moisture(H2O):0-100%RS(given in ppm)

Accuracy

  • Gases*:±5%or±LDL(Lower Detection Limit),which ever is greater
  • Moisture:±2%RH

Frequency

  • Configurable from once per hour to once

every4weeks

  • Faster sampling automatically triggered upon alert level reached

Transfix DGA 900

The Kelman DGA 900 TAPTRANS is the next generation 9-gas on-line transformer multi gas DGA (Diagnostic Gas Analyzer) monitor. Built from the DGA 900 platform, the TAPTRANS extends the capability beyond measuring a single transformer main oil tank.

Features

  • Provides remote alert and multi-gas diagnostic of deteriorating transformer condition
  • Expedites operational decisions without needing to go to site for manual oil sampling
  • Issues can be detected in their infancy, avoiding unexpected failures and facilitating planned outages.
  • Provides early identification of arcing issues before they become critical failures
  • Ability to perform Duval’s triangle DGA diagnostic

Applications

Power Utilities:

  • Middle of the road solution for medium-criticality transformers
  • Monitoring together with remote exploratory diagnostic

Industrial Plants:

  • Reduces the risk of process interruption due to power failure
  • Minimizes costly production downtime

Technical Specifications

Technology

  • Automated head space gas extraction
  • Photo-acoustic spectroscopy(PAS)gas measurement
  • Thin film capacitive moisture sensor
  • Immersed Fiber Optic Oxygen sensor

Frequency

  • Configurable from once per hour to once every 4weeks
  • Faster sampling automatically triggered upon alert level reached
  • “Rapid Mode” provide sharp indication of the evolution of the gasses indicated below in~30 minutes
  • Faster sampling automatically triggered upon alert level reached
Details LDL UDL Accuracy* Repeatability AvailableinRapidMode
Hydrogen(H₂) 5- 5,000ppm ±LDLor±5% <3%
Carb. Monox. (CO) 1- 50,000ppm ±LDLor±3% <2%
Methane(CH₄) 2- 50,000ppm ±LDLor±3% <2%
Acetylene (C₂H₂) 0.5- 50,000ppm ±LDLor±3% <2%
Ethylene (C₂H₄) 1- 50,000ppm ±LDLor±3% <2%
Carb.Diox.(CO₂) 20- 50,000ppm ±LDLor±3% <3%
Ethane(C₂H₆) 1- 50,000ppm ±LDLor±3% <2%
Oxygen(O₂) 100- 50,000ppm ±LDLor±5% <2%
Nitrogen(N₂)** 10,000- 100,000 ppm ±LDLor±15%
Moisture(H₂O) 0- 100%RS (in ppm) ±3%RH <3%