MINI AC/DC LOAD CLAMP TESTER

M-230

FEATURES

  • Useful for DC A measurement for automobile service.
  • Data-hold function. Especially useful when working in dark or hard to get areas
  • Accurate gearing mechanism for closing of CT.
  • Ultra compact size.

M-240

FEATURES

  • Ultra compact size and high accuracy AC/DC clamp-on tester.
  • Data hold function. Especially useful when working in dark or hard to get areas.
  • Wide range of current measurments from AC/DC 0.01A to 200A with 30㎜φ CT.

Safety Standard: Meets the requirements for double insulation to IEC 61010-1(2010), IEC 61010-2-032(2002) installation Category  II 600V phase to earth, Category  III 300V phase to earth.

E.M.C Standard: The instrument meets EN 61326 (2006).

M-250

FEATURES

  • Ultra compact size and high accuracy AC/DC clamp-on tester.
  • Data hold function. Especially useful when working in dark or hard to get areas.
  • Wide range of current measurments from AC/DC 0.1A to 1000A with 40㎜φ CT.

Safety Standard: Meets the requirements for double insulation to IEC 61010-1(2010), IEC 61010-2-032(2002) installation Category  II 600V phase to earth, Category  III 300V phase to earth.

E.M.C Standard: The instrument meets EN 61326 (2006).

Model 230 240 250
Safety standard - IEC 61010-1, IEC61010-2-032 CAT.Ⅱ 600V or CAT.Ⅲ 300V
EMC standard - EN61326
Measuring method Dual integration mode
Display 3.5 digit LCD
Range (AC/DC Current) 20A 200A 20A 200A 200A 1000A
Resolution 10mA 100mA 10mA 100mA 100mA 1A
Accuracy AC Current (50/60Hz) ±1.0%rdg±5dgt ±1.5%rdg±5dgt
(0〜150.0A)
±2.5%rdg±5dgt
(150.0〜199.9A)
±1.5%rdg±5dgt ±2.0%rdg±5dgt
(0〜150.0A)
±3.0%rdg±5dgt
(150〜199.9A)
±1.5%rdg±5dgt ±1.5%rdg±5dgt
Accuracy DC Current ±1.0%rdg±3dgt ±1.5%rdg±3dgt
(0〜150.0A)
±2.5%rdg±3dgt
(150.0〜199.9A)
±1.5%rdg±3dgt ±2.0%rdg±3dgt
(0〜150.0A)
±3.0%rdg±3dgt
(150〜199.9A)
±1.5%rdg±5dgt ±1.5%rdg±5dgt
Jaw opening capability 23㎜φ 30㎜φ 40㎜φ
Overload indication Blanking of all digits except MSD1
Maximum indication 1999
Low battery indication "B" mark on LCD readout
Sampling 2 times/s
Limitation of circuit voltage Less than AC 600V
Operating temperature 0 ℃ to 40℃,< 80% RH
Storage temperature -10 ℃ to 60℃,< 70% RH
Power supply SR-44(1.55V)×2 or LR-44×2
Power consumption 3mW
Battery life SR-44 : 200 hours,LR-44 : 100 hours
Size 48(W)×146(H)×20(D)㎜ 44(W)×146(H)×20(D)㎜(H) 68.5(W)×175(H)×23(D)㎜
Weight Approx. 100g Approx. 80g Approx. 166g
Accessories Soft case ……1 Instruction manual ……1 Batteries(LR-44) ……2