LIVE LINE CLAMP INSULATION RESISTANCE TESTER

MLIT-1

FEATURES

  • Easy and convenient live line insulation measurements for servomotor, equipments and power line.
  • 10MΩ〜20MΩ insulation resistance measurements with super accurate ZCT.
  • The least influence from external magnetic field and noise.
  • Phase voltage and leakage is also measurable.
  • 99 sets of memory storage function for measured data.

PRIMARY SPECIFICATIONS

1) VOLTAGE INPUT SECTION

Voltage Input : Phase voltage (AC 50〜500V) Single phase detection
Phase Detection Method : (Single phase detection is also used for three phase circuit)
Input Impedance : More than 1MΩ
Input Frequency : 50Hz or 60Hz switchable
Resolution : 0.1V
Input Method : Direct input by test lead

2) CURRENT DETECTION SECTION

Detection Method : Split core type ZCT
CT Inside Size : φ30㎜
CT Opening/Closing : Manual slide method
Withstanding Voltage : AC 2000V, 1 minute

3) MEASUREMENT SECTION

Measuring Function : AC Leakage current/line current, AC voltage, Insulation resistance Measuring range
AC Leakage/Line Current : 0〜AC 200.0μA/2mA/20mA/200mA (Auto-ranging)
AC Voltage : 0〜500.0V (1 range) Resolution
AC Leakage/Line Current : 0.1μA
AC Voltage : 0.1V
Insulation Resistance : Computation by current and voltage
Input Frequency : 45Hz 65Hz (50Hz/60Hz switchable)
A/D Conversion : Dual slope integration method
AC Conversion : Average sensing, true rms reading method
Display : LCD, max. 1999 count with annunciator
Over Range Indication : “OL” mark on LCD
Data Hold Indication : “DH” mark on LCD
Low Battery Indication : “B” mark on LCD
Sampling Rate : 2 times/sec (Without internal calibration)
Memory Storage : Measuring Data 99 sets
Operating Temperature : 0〜40ºC, < 85%RH (without condensation)
Storage Temperature : -10〜60ºC, < 70%RH (without condensation)
Withstanding Voltage : AC 2000V/1 minute (between CT and handle)
Limitation of Circuit Voltage : Less than AC 500V for insulated cable
Auto Power Off : Approx. 10 minutes after last key operation
Power Supply : LR6, AM-3 or AA size Alkaline battery×4

4) ACCURACY
Leakage (Io), Line (I), Resistive (Ior)

Range Min Resolution Accuracy(45〜65Hz)
Voltage 0.1V 0~499.9V±1.0%rdg±10dgt
I,Io 200μA 0.1μA 0~199.9μA±1.0%rdg±10dgt
2mA 0.001mA 0.200~1.999mA±1.0%rdg±10dgt
20mA 0.01mA 2.00~19.99mA±1.0%rdg±10dgt
200mA 0.1mA 20.0~220.0mA±1.0%rdg±10dgt
Ior 200μA 0.1μA 0~199.9μA±1.5%rdg±15dgt
2mA 0.001mA 0.200~1.999mA±1.5%rdg±15dgt
20mA 0.01mA 2.00~19.99mA±1.5%rdg±15dgt
200mA 0.1mA 20.0~220.0mA±1.5%rdg±15dgt